Evaluating 3D Intraoral Scans for Accurate Dental Plaque Detection: A Comparative Clinical Study

Evaluating 3D Intraoral Scans for Accurate Dental Plaque Detection: A Comparative Clinical Study

Highlight

  • 3D intraoral scan (IOS) imaging shows high sensitivity in detecting dental plaque compared to conventional visual clinical assessment.
  • Specificity of IOS plaque detection is lower, indicating a tendency to overestimate plaque presence, which improves after plaque disclosure.
  • IOS enables capture and audit of plaque assessment over visits, potentially enhancing clinical monitoring and patient management.

Study Background

Dental plaque accumulation remains a primary etiological factor in the development of dental caries and periodontal diseases, significantly impacting oral health worldwide. Accurate detection and quantification of plaque are vital for tailored preventive strategies and treatment monitoring. Traditionally, plaque scoring is performed by visual clinical examination using indices such as the Silness and Löe index, both undisclosed and post-plaque disclosure agent application. However, visual assessment is subjective, time-consuming, and limited by examiner variability. Advances in digital dentistry have introduced 3D intraoral scanning (IOS) technologies that provide detailed imaging of oral structures. These scans potentially offer objective, reproducible plaque assessment by digitally capturing plaque deposition patterns. Nonetheless, the diagnostic validity of IOS-derived plaque detection compared to conventional clinical scoring requires robust investigation.

Study Design

This cross-sectional study conducted at a single clinical site recruited 60 adult participants aged 19 to 74 years with a minimum of 20 natural teeth. Each participant underwent a sequence of evaluations: – Initial 3D IOS imaging followed by clinical visual plaque scoring on four sites per tooth using the Silness and Löe plaque index, without plaque disclosure. – Application of a plaque-disclosing agent with repeated clinical plaque scoring. – A second IOS performed post-disclosure. – After a washout period, clinical examiners reassessed plaque directly on IOS images pre- and post-disclosure, including inter- and intra-examiner assessments to analyze reproducibility. The primary comparator was the clinical visual assessment, considered the reference standard.

Key Findings

The clinical comparison between undisclosed and disclosed plaque scoring revealed poor agreement, with plaque detected substantially increasing post-disclosure. This finding corroborates the known enhanced visibility of plaque after using disclosing agents. Regarding IOS accuracy: – Sensitivity of IOS plaque scoring was consistently high both before and after disclosure (pre-disclosure sensitivity: 90.4% and 96.1%; post-disclosure: 91.0% and 93.9%), indicating effective plaque detection capabilities of IOS. – Specificity was notably lower, especially for undisclosed plaque (30.3% and 44.9%), but it improved after disclosure (49.2% and 55.9%). This reflects a tendency of IOS to overestimate plaque presence, which becomes less pronounced after plaque disclosure. Plaque assessments performed directly on scanned images post-disclosure demonstrated improved inter-examiner (79.7% to 85.7%) and intra-examiner agreement (87.5% to 91.5%), indicating good reproducibility when using IOS. Significantly, IOS-based plaque scoring identified more plaque-positive sites than clinical assessment, with overestimation rates reduced after disclosure (29.4% pre-disclosure vs. 14.1% post-disclosure). This suggests IOS may detect plaque accumulations that are less visible to the naked eye.

Expert Commentary

The study highlights the promising diagnostic utility of IOS technology in plaque assessment while underscoring important considerations. The high sensitivity indicates that IOS is effective at detecting existing plaque, which is critical in preventive dentistry to avoid under-treatment. However, the lower specificity and overestimation indicate a limitation that could lead to potential overdiagnosis if used as a sole modality. Overestimation may arise from technical artifacts or interpretation challenges inherent in digital imaging. Clinicians should interpret IOS findings in the context of clinical examination and plaque disclosure results for accurate decision-making. Enhanced inter- and intra-examiner reliability on post-disclosure scans suggests that training and standardized protocols can further improve assessment consistency. Integration of IOS into routine practice offers benefits such as digital record keeping, longitudinal tracking of plaque, patient education, and tele-dentistry applications. Study limitations include the single-site design and relatively small sample size, which may affect generalizability. Larger multicenter studies are warranted to validate these findings across diverse populations and scanner technologies.

Conclusion

The study demonstrates that 3D intraoral scan imaging exhibits high sensitivity and acceptable reproducibility for dental plaque detection compared to conventional clinical assessment. Although specificity is moderate, especially before plaque disclosure, diagnostic accuracy improves with disclosing agents. IOS technology offers a valuable adjunct to traditional visual plaque scoring, with potential to enhance early detection, patient monitoring, and clinical documentation. Its adoption in dental practice could improve oral health outcomes by enabling objective, reproducible, and revisitable plaque assessments. Ongoing research should focus on refining imaging algorithms to reduce overestimation and integrating IOS with clinical workflows.

Funding and ClinicalTrials.gov

The article did not report specific funding sources or ClinicalTrials.gov registration.

References

1. Wright M, West N, Nørrisgaard PE, Newcombe RG, Davies M, West NX. Investigating the utility of 3D-intraoral scan imaging to score plaque compared to visual clinical assessment. J Dent. 2026 Jul 20;174:106920. PMID: 42476252. 2. Silness J, Löe H. Periodontal Disease in Pregnancy II. Correlation between Oral Hygiene and Periodontal Condition. Acta Odontol Scand. 1964;22:121–135. 3. Hausmann E, Hagenfeld D, Splieth C. Digital Technologies for Detecting and Quantifying Dental Plaque: Systematic Review. Clin Oral Investig. 2022;26(6):4137–4148. 4. Newman MG, et al. Carranza’s Clinical Periodontology. 13th Edition. Elsevier; 2018.