Posted inCritical Care news Respiratory
Digital twins suggest APRV can lower mechanical power and tidal recruitment versus PCV in ARDS — modeling evidence and clinical implications
High-fidelity digital twins of 98 ARDS patients indicate APRV (Phigh 25/Plow 0, long Tinsp, short Tlow to 75% peak expiratory flow) reduced mechanical power by ~32% and tidal recruitment by ~34% versus recorded PCV, at the cost of controlled hypercapnia; clinical trials are needed.